- Omicron Cmc 256 6 User Manual Pdf Online
- Omicron Cmc 256 Plus Price
- Omicron Cmc 256 6 User Manual Pdf 2 10
- Omicron Cmc 356 Manual Pdf
Resolution 6 mV Connection 4 mm (0.16 in) banana sockets/comb. 7 For the control of CMC 156 EP via the USB port of the PC, a CMUSB-P USB to Parallel Converter is included in delivery Binary outputs, relays. OMICRON electronics GmbH Created Date. Omicron Cmc 256 6 User Manual To get started finding online user manuals omicron cmc 256 manual, the very first PDF online downloads omicron cmc 256-6 manual from legal resources. Omicron cmc 256 6 user manual, Developed by Firebrand Games, the team responsible for the award-winning Race Driver: Create and Race, the NDS edition.
The CMC 256plus is the first choice for applications requiring very high accuracy. This unit is
not only an excellent test set for protection devices of all kinds but also a universal calibra-
tion tool. Its high precision allows the calibration of a wide range of measuring devices,
including: electricity meters of class 0.2, measuring transducers, power quality measurement
devices and phasor measurement units (PMU). Its unique accuracy and flexibility make the
CMC 256plus ideal for protection and measurement equipment manufacturers for research
and development, production and type testing. The CMC 256plus can either be operated by
the Test Universe software running on a PC or by the front panel control device CMControl.
CMC 256plus: 6 Phase Current + 4 Phase Voltage Test Set and Universal Calibrator
Current generators
Setting range 6-phase AC (L-N)
Omicron Cmc 256 6 User Manual Pdf Online
6 x 0 .. 12.5 A
3-phase AC (L-N)
3 x 0 .. 25 A (Group A II B)
1-phase AC (3L-N)
1 x 0 .. 75 A (Group A II B), 2 x 0 .. 37.5 A
DC (3L-N)
1 x 0 .. ±35 A (Group A II B), 2 x 0 .. ±17.5 A
Power
6-phase AC (L-N)
6 x 80 VA typ. at 8.5 A, 6 x 70 VA guar. at 7.5 A
3-phase AC (L-N)
3 x 160 VA typ. at 17 A (Group A II B)
3 x 140 VA guar. at 15 A (Group A II B)
1-phase AC (3L-N)
1 x 480 VA typ. at 51 A (Group A II B),
2 x 240 VA at 25.5 A
1 x 420 VA guar. at 45 A (Group A II B),
2 x 210 VA at 22.5 A
1-phase AC (L-L)
1 x 320 VA typ. at 8.5 A (Group A II B),
2 x 160 VA at 8.5 A
1 x 280 VA guar. at 15 A (Group A II B),
2 x 140 VA at 7.5 A
1-phase AC (L-L-L-L) 1 x 320 VA typ. at 8.5 A
(40 VRMS, Group A and B in series)
1 x 280 VA guar. at 7.5 A
(40 VRMS, Group A and B in series)
DC (3L-N)
1 x 480 W typ. at ±35 A (Group A II B),
2 x 240 W at ±17.5 A
1 x 470 W guar. at ±35 A (Group A II B),
2 x 235 W at ±17.5 A
500
400
300
200
100
0
0
10
25
50
75
Output current / A
Group A
and B in
series
1-phase
AC (L-L)
3-phase AC (L-N)
1-phase AC (L-N)
Output po
w
er (typ.) / V
A
Accuracy
2
error < 0.015 % rd.
3
+ 0.005 % rg.
3
typ.
at 0 .. 12.5 A
error < 0.04 % rd. + 0.01 % rg. guar.
at 0 .. 12.5 A
Distortion (THD+N)
4
< 0.025 % typ., < 0.07 % guar.
Ranges
1.25 A / 12.5 A (Group A, B) or
2.5 A / 25 A (Group A II B)
Resolution (for respective range)
50 µA / 100 µA / 500 µA / 1 mA
Max. compliance voltage (L-N)/(L-L) 15 Vpk / 60 Vpk
Connection
4 mm (0.16 in) banana sockets / combination
socket (Group A only)
Voltage generators
Setting range
4-phase AC (L-N)
4 x 0 .. 300 V (VL4(t) automatically
calculated: VL4 = (VL1+VL2+VL3)*c
or freely programmable)
3-phase AC (L-N)
3 x 0 .. 300 V
1-phase AC (L-L)
Synergy air elite user manual. 1 x 0 .. 600 V
DC (L-N)
4 x 0 .. ±300 V
Power
3-phase AC (L-N)
3 x 100 VA typ. at 100 .. 300 V
3 x 85 VA guar. at 85 .. 300 V
4-phase AC (L-N)
4 x 75 VA typ. at 100 .. 300 V
4 x 50 VA guar. at 85 .. 300 V
1-phase AC (L-N)
1 x 200 VA typ. at 100 .. 300 V
1 x 150 VA guar. at 75 .. 300 V
1-phase AC (L-L)
1 x 275 VA typ. at 200 .. 600 V
1 x 250 VA guar. at 200 .. 600 V
DC (L-N)
1 x 420 W typ. at ±300 V
1 x 360 W guar. at ±300 V
Output voltage / V
Output po
w
er (typ.) / V
A
1-phase AC (L-L)
1-phase AC (L-N)
3-phase AC (L-N)
4-phase AC (L-N)
300
250
200
150
100
50
https://fargol.netlify.app/intelilite-amf-9-user-manual-pdf.html. InteliLite 9. Next generation of Controller for single gen-set applications. Order code: IL3LAMF9BAA. Ask for more info NOW. InteliLite AMF 20. Auto Mains Failure (AMF) gen-set controller InteliLite MRS 11. Manual & Remote Start (MRS) gen-set controller. ComAp Products Single gen-set controllers InteliLite InteliLite NT AMF 9. Check the successor. InteliLite NT AMF 9. Auto Mains Failure (AMF) Gen-set Controller. Order code: IL-NT AMF 9. Ask for more info NOW. InteliLite NT AMF 25. Auto Mains Failure (AMF.
0
0
100
200
300
400
500
600
Accuracy
5
error < 0.015 % rd.
3
+ 0.005 % rg.
3
typ. at 0 .. 300 V
error < 0.04 % rd. + 0.01 % rg. guar.
at 0 .. 300 V
Distortion (THD+N)
4
0.015 % typ., < 0.05 % guar.
Ranges
150 V / 300 V
Resolution
5 mV / 10 mV in range 150 V / 300 V
Connection
4 mm (0.16 in) banana sockets /
combination socket (1,2,3,N)
Generators, general
Frequency
range sine signals
10 .. 1000 Hz
range harmonics /
interharmonics
6
10 .. 3000 Hz
range transient signals
6
DC .. 3.1 kHz
accuracy / drift
±0.5 ppm / ±1 ppm
resolution
< 5 µHz
Phase
angle range
-360° .. +360°
resolution
0.001°
error at 50 / 60 Hz
< 0.005° typ., < 0.02° guar.
Bandwidth (-3 dB)
3.1 kHz
Simulated power
S, P (calibration
of energy meters)
accuracy
7
error < 0.05 % rd. typ., < 0.1 % rd.
guar.
temperature drift
< 0.001 % / °C typ., < 0.05 % / °C guar.
Technical Data
Omicron Cmc 256 Plus Price
1
1
All data specified are guaranteed, except where indicated otherwise.
OMICRON guarantees the specified data for one year after factory calibration,
within 23 °C ±5 °C (73 °F ±10 °F) in the frequency range from 10 to 100 Hz and
after a warm-up phase > 25 minutes
2
Rload: 0 .. 0.5 W
3
rd. = reading, rg. = range
4
THD+N: Values at 50/60 Hz, > 1 A / 20 V with 20 kHz bandwidth
5
Rload: > 250 W
6
Amplitude derating at > 1000 Hz
7
Data are valid from 0.1 to 12.5 A (current amplifier A or B) and 50 to 300 V
(voltage amplifier) at 50/60 Hz
Permissible load for current outputs:
Range 1.25 A: 0 to 1 W and 1 VA max., cos ϕ = 0.5 to 1
Range 12.5 A: 0 to 0.5 W and 6 VA max., cos ϕ = 0.5 to 1
Permissible load for voltage outputs:
10 VA max. at 50 to 300 V, cos ϕ = 0.5 to 1
Omicron Cmc 256 6 User Manual Pdf 2 10
CMC 256plus
- Test Set Overview
- CMControl
- Test Universe Software
- Software
- QuickCMC
- State Sequencer
- Ramping
- TransPlay: Transient Playback Tool
- Harmonics
- Binary I/O Monitor
- CB Simulation
- Pulse Ramping
- Overcurrent
- Overcurrent Characteristics Grabber
- Distance
- Differential
- Autoreclosure
- Advanced Distance
- VI Starting
- Advanced Differential
- Annunciation Checker
- Synchronizer
- Transient Ground Fault
- Advanced TransPlay
- Meter
- Transducer
- OMICRON Control Center
- Pause Module, Text View, ExeCute
- Test Object Definition with XRIO ®
- PTL Protection Testing Library
- CM Engine Programming Interface
- cm_FCS Field Calibration Software
- QuickCMC
- Additional Software
- NetSim Network Simulation Software
- EnerLyzer TM
- TransView
- PQ Signal Generator
- NetSim Network Simulation Software
- IEC 61850 Testing Tools
- IEDScout
- GOOSE
- Sampled Values (SV)
- IEC 61850 Package
- SVScout
- CMC 850 Package
- IEDScout
- Scheme Testing Tools
- CommPro
- LogicPro
- DLogicPro
- CommPro
- Test Sets
- CMC 356: 6 Phase Current + 4 Phase Voltage Test Set and Commissioning Tool
- CMC 353: 3 Phase Current + 4 Phase Voltage Test Set and Commissioning Tool
- CMControl: Front Panel Control for CMC Test Sets
- CMC 850: IEC 61850 Test Set
- CMC 356: 6 Phase Current + 4 Phase Voltage Test Set and Commissioning Tool
- Amplifier Units
- CMA 156: 6 Phase Current Amplifier (6 x 25 A)
- CMS 156: 3 Phase Voltage and Current Amplifier (3 x 250 V, 3 x 25 A)
- CMA 156: 6 Phase Current Amplifier (6 x 25 A)
- Accessories
- CMGPS Synchronization Unit
- CMIRIG-B Interface
- CMB IO-7
- Scanning Heads and Related Accessories
- Cable Connector for REF 54x
- CMLIB A Low Level Signal Connector
- CPOL Polarity Checker
- C-Probe 1 Current Clamp
- C-Shunt 1
- C-Shunt 10
- Converter optical – electrical
- CMUSB-P USB to Parallel Converter
- Generator Combination Cable
- CMC Wiring Accessory Package
- Standard CMx Accessories
- Transport Cases
- Foldable Stand
- CM Recloser and Sectionalizer Test Cables
- CMGPS Synchronization Unit
- Other Test Equipment
- CPC 100 & CP CU1
- CT Analzyer
- Contacts
- CT Analzyer
- CPC 100 & CP CU1
Low level outputs
1
Number of outputs
6 (12 with Option LLO-2)
Setting range
0 .. ±10 Vpk
Max. output current
1 mA
Accuracy
error < 0.025 % typ., < 0.07 % guar.
at 1 .. 10 Vpk
Resolution
250 µV
Schwinn 150 Manuals & User Guides. User Manuals, Guides and Specifications for your Schwinn 150 Exercise Bike. Database contains 1 Schwinn 150 Manuals (available for free online viewing or downloading in PDF): Owner's manual. View and Download Schwinn 150 owner's manual online. 150 Exercise Bike pdf manual download. Schwinn exercise bike user manual (28 pages) Exercise Bike Schwinn 112 Owner's Manual. Schwinn exercise bike user manual (34 pages) Exercise Bike Schwinn 112 Parts List, Full Size Hardware Chart, Product Illustration, Assembly Instructions. Schwinn ® Fitness Manuals. Manuals are also available in Spanish and French. Assembly and Owner's manuals for Schwinn ® products. Adobe Reader is required to view and print these documents (PDF). Schwinn stationary bike used. View online Owner's manual for Schwinn 150 Exercise Bike or simply click Download button to examine the Schwinn 150 guidelines offline on your desktop or laptop computer.
Distortion (THD+N)
2
< 0.015 % typ., < 0.05 % guar.
Unconventional CT/VT simulation
linear, Rogowski (transient and sinewave)
Overload indication
yes
Isolation
SELV
Usability
completely independent from internal
amplifier outputs
Connection
16 pin combination socket (rear side)
Auxiliary DC supply
Voltage ranges
0 .. 264 VDC, 0.2 A / 0 .. 132 VDC,
0.4 A / 0 .. 66 VDC, 0.8 A
Power
max. 50 W
Accuracy
error < 2 % typ., < 5 % guar.
Connection
4 mm (0.16 in) banana sockets
Binary inputs
Number
10
Trigger criteria
Toggling of potential-free contacts or DC
voltage compared to threshold voltage
Input characteristics
0 .. ±600 VDC threshold or
potential-free
Ranges
100 mV / 1 V / 10 V / 100 V / 600 V
Resolution of threshold
±2 mV, ±20 mV, ±200 mV, ±2 V,
±20 V in ranges
Sample rate
10 kHz (resolution 100 µs)
Time stamping accuracy
±0.00015 % of rd.
3
±70 µs
Max. measuring time
infinite
Debounce / Deglitch time
0 .. 25 ms / 0 .. 25 ms
Counting function
< 3 kHz at pulse width > 150 µs
Galvanic isolation
5 galvanically isolated groups
(2+2+2+2+2)
Max. input voltage
CAT IV / 150 V, CAT III / 300V, CAT II /
600 V (850 Vpk)
Connection
4 mm (0.16 in) banana sockets
Counter inputs 100 kHz
Number
2
Max. counting frequency
100 kHz
Pulse width
> 3 µs
Threshold voltage
6 V
Voltage hysteresis
2 V
Max. input voltage
±30 V
Isolation
SELV
Connection
16 pin combination socket (rear side)
Trigger on overload
Supported generators
Current generators
Timer accuracy
error < 1 ms
Binary outputs, relays
Type
potential-free relay contacts, software
controlled
Number
4
Break capacity AC
Vmax: 300 VAC / Imax: 8 A /
Pmax: 2000 VA
Break capacity DC
Vmax: 300 VDC / Imax: 8 A /
Pmax: 50 W
Connection
4 mm (0.16 in) banana sockets
Binary outputs, transistor
Type
open collector transistor outputs
Number
4
Update rate
10 kHz
Imax
5 mA
Connection
5600 / 5600 EconominderOwner's ManualFor questions or in case of emergency, please call your local service technician (preferably the one who installed the system).Product Features, Benefits, & Job Specification SheetCongratulations on the purchase of your new water treatment system with the 5600 control valve. Fleck water softener systems manuals.
16 pin combination socket (rear side)
DC voltage measuring input
Measuring range
0 .. ±10 V
Accuracy
error < 0.003 % rg.
3
typ.,
< 0.02 % rg. guar.
Input impedance
1 MW
Connection
4 mm (0.16 in) banana sockets
DC current measuring input
Measuring range
0 .. ±1 mA, 0 .. ±20 mA
Accuracy
error < 0.003 % rg.
3
typ.,
< 0.02 % rg. guar.
Input impedance
15 W
Connection
4 mm (0.16 in) banana socket
Analog AC+DC measuring inputs
4
Type
AC + DC analog voltage inputs
(current measurement with external
current clamps or shunt resistors)
Number
10
Nominal input ranges (RMS values)
100 mV, 1 V, 10 V, 100 V, 600 V
Amplitude accuracy
error < 0.06 % typ., < 0.15 % guar.
Bandwidth
DC .. 10 kHz
Sampling frequency
28.44 kHz, 9.48 kHz, 3.16 kHz
Input impedance
500 kW // 50 pF
Transient input buffer at 28 kHz
3.5 s for 10 input channels / 35 s for 1
input channel
Transient input buffer at 3 kHz
31 s for 10 input channels / 5 min. for 1
input channel
Transient trigger
threshold voltage, power quality trigger:
sag, swell, harmonic, frequency,
frequency change, notch
Measurement functions
I (AC + DC), V (AC + DC), phase,
frequency, power, harmonics,
transient recording, event recording,
trend recording
Input overload indication
yes
Omicron Cmc 356 Manual Pdf
Input protection
yes
Max. input voltage
CAT IV / 150 V, CAT III / 300V, CAT II /
600 V (850 Vpk)
Galvanic isolation
5 groups (2+2+2+2+2)
Connection
4 mm (0.16 in) banana sockets
(combined with binary inputs)
Time Synchronization
Timing accuracy
IRIG-B synchronization with CMIRIG-B
GPS synchronization with CMGPS
error < 1 µs typ., < 5 µs guar.
error < 1 µs typ., < 5 µs guar.
To external voltage
Reference signal on binary input 10:
10 .. 300 V / 40 .. 70 Hz
With the unique PermaSync functionality (supported by TU 2.30 or higher), analog
and Sampled Values outputs stay permanently in sync with the internal CMC time
reference. In combination with the optional CMIRIG-B interface box, PermaSync
additionally allows the continuous synchronization of the output quantities with
an external IRIG-B time protocol or an external PPS signal. With CMIRIG-B it is also
possible to transmit the internal PPS signal of the CMC to the device under test (e.g.
PMUs or IEDs stimulated with a synchronized Sampled Values data stream).
1
For directly testing relays with low level inputs by simulating signals from non
conventional CTs and VTs with low level interfaces and for controlling external
amplifier units
2
THD+N: Values at 50/60 Hz, 20 kHz measurement bandwidth, nominal value, and
nominal load
3
rd. = reading, rg. = range
4
Up to three inputs can be used for measuring RMS values, frequency, and phase
angle without the EnerLyzer software license. Full functionality requires EnerLyzer
software license